Home About Us News Events See Full Inventory Re+ 2026 Safe Harbor Custom Procurement Contact Us Login

Buyer’s Guide

TOPCon vs PERC vs HJT: Solar Cell Technology Choices for Bulk Buyers

1000containers Team, November 14, 2026, 7 min read

Cell technology is one of the first forks a wholesale buyer hits once price per watt and certifications are settled. For the broader sourcing picture, see our guide on where to buy bulk solar panels. This article walks through what’s actually changing between PERC, TOPCon, and HJT cells, and why it affects availability as much as performance.

Overview

PERC, TOPCon, and HJT (heterojunction) are the three cell architectures that dominate commercial solar module production today, alongside a smaller back-contact (BC) segment. Each trades off manufacturing cost, efficiency, temperature performance, and degradation differently, and the market mix between them has shifted meaningfully over the past two years, which affects what a buyer can actually source at scale and at what price.

The market share shift, by the numbers

Tracking data on listed commercial modules shows TOPCon’s share rising steadily while PERC’s share falls every period measured, with TOPCon overtaking PERC in early 2025:

Period

TOPCon

PERC

HJT

BC

January 2023

24%

50%

18%

7-8%

December 2023

33%

44%

18%

7-8%

December 2024

38%

38%

14-18%

7-8%

June 2025

39%

35%

18%

7-8%

TOPCon marginally overtook PERC in early 2025 and has held the larger share since. PERC has declined in every measured period. HJT ticked up through 2025, helped by new manufacturer entrants, while BC has stayed flat in roughly the same 7% to 8% band throughout.

What’s actually different between them

PERC is the most mature and lowest-cost technology to manufacture, which is why it still fills a meaningful share of global production, but new PERC-only production capacity has largely stopped being built as manufacturers retool lines for TOPCon. TOPCon adds a passivated rear contact layer that pushes cell efficiency higher and, based on the named-manufacturer figures in warranty documents, tends to carry a lower annual degradation rate than older PERC cells. HJT combines crystalline silicon with thin amorphous layers, giving it the best temperature coefficient of the three (less output loss in hot conditions) and typically the highest efficiency, at a correspondingly higher price per watt. BC (back-contact) cells move all wiring to the rear of the cell for a cleaner appearance, used mostly where aesthetics matter more than cost.

What this means for a bulk order today

Because manufacturers are actively shifting capacity toward TOPCon, buyers sourcing at container or truckload volume should expect TOPCon modules to be the default recommendation from most Tier 1 suppliers going forward, with PERC increasingly limited to clearing existing inventory at a discount rather than new production runs. HJT remains a smaller, premium-priced slice of the market, worth considering specifically for high-temperature sites or where the extra efficiency materially changes a project’s footprint.

Before locking in a cell technology for a bulk order, it’s worth confirming a few things with the supplier directly:

  • Current price per watt for each technology at the order’s actual volume, since the TOPCon-to-PERC price gap has narrowed as TOPCon capacity has scaled

  • Bifacial compatibility, since most new TOPCon and HJT lines ship bifacial by default while legacy PERC inventory may not

  • Documented degradation and warranty terms for the specific SKU, not the cell technology in general

  • Lead time and available volume, since production capacity is shifting and older PERC lines may have limited remaining runs

Frequently asked questions

Is PERC being phased out entirely?

Not immediately, but its share has fallen every period in the available tracking data, and most new manufacturing capacity is being built for TOPCon instead. Buyers should expect PERC’s remaining market share to keep shrinking and availability of new PERC production to tighten over time.

Is TOPCon simply a direct upgrade over PERC at the same price?

TOPCon generally offers higher efficiency and, based on warranted degradation figures from major manufacturers, a lower annual output loss than older PERC cells. The price premium has narrowed considerably as TOPCon capacity has scaled, but buyers should still compare actual quoted price per watt rather than assume the technologies are now priced identically.

When does HJT’s higher price actually pay off?

HJT’s main advantages are its efficiency and its temperature coefficient, meaning it loses less output as panel temperature rises. That makes it most worth the premium on sites with high ambient heat or where rooftop space is constrained enough that squeezing out extra efficiency per panel materially reduces the total module count needed.

1000containers sources TOPCon, PERC, and HJT modules from Tier 1 manufacturers for full truckload and container orders. See current inventory and request a quote.

Subscribe to our newsletter for solar industry and inventory updates

© 2026 1000containers Holdings LLC.

Subscribe to our newsletter for solar industry and inventory updates

© 2026 1000containers Holdings LLC.